Chapter 4
Commissioning
2100.4400.32
- 4.12 -
E-2
2.2.3
ATSC: Signal Feed
2.2.3.1
Configuring Input Interfaces and Automatic Input Selection
Setting data format for transport streams
1. Select TV Settings > Input > Input Config.
The Input Config window opens.
2. Under TS Format 1, select the data format for transport stream 1. If AUTO is selected,
the data format is detected automatically.
3. Under TS Format 2, select the data format for transport stream 2 if a second signal feed
(signal standby) is used. If AUTO is selected, the data format is detected automatically.
Setting automatic input switchover
The following settings are used to preselect the operating input and to configure the behav-
ior of the automatic input switchover:
Check Time Back
For setting a delay time (0 to 60 s) which must elapse before switching 
back to the preselected operating input after switching over from the 
standby input (which is no longer active)
The function has no effect when seamless switching is active and/or the 
priority mode is set to EQUAL.
On Loss Of Input
For setting the behavior in the event of a defective input signal (synchro-
nization error)
– No Mute: The output signal is not suppressed (only effective with 
MFN)
– Mute: The output signal is suppressed if the data rate is incorrect (this 
feature always applies to SFN)
Type Of Loss Of Input
Selection:
– Warning: If the input signal fails, only a warning will be generated.
– Fault: If the input signal fails, an additional sum fault will be generated 
after the time set under Fail Delay Time has elapsed. In the case of 
transmitter standby, switchover to the second transmitter takes place. 
Fail Delay Time
For setting a delay time which must elapse after an input signal dropout 
before a sum fault is generated.
Setting item
Description