5.2.2.1 Device
Address
The working address for all RT30 devices shall be 45583730
h
(‘EX30’ ASCII).
5.2.2.2 Supported
Commands
While the RT30 shall accept all commands defined in the Inter-Module RF Communications specification without
system failure, the TU shall only send, and the RU shall only act upon, the following commands:
system failure, the TU shall only send, and the RU shall only act upon, the following commands:
• Alarm
Status
• Hello
• Beep
Code
• Comm
Channel
Change
5.3 S
WITCHES
5.3.1
TU Power/Mode Switch
This switch has three positions:
• Off – The unit is off, and battery power is completely disabled.
• NCV – The internal NCV circuit is enabled. This setting can be overridden by attaching the External
• NCV – The internal NCV circuit is enabled. This setting can be overridden by attaching the External
Probe.
• Light – The LDR circuit is enabled. This setting can also be overridden by attaching the External
Probe.
5.3.2
TU Calibrate/Channel Switch
This switch is a momentary switch. It has two functions:
• Calibrate – If the switch is pressed for more than 100mS, but less than 5 seconds, the RT30 shall enter
Calibrate Mode. A ‘short’ press is also used to select channels.
• Channel – If the switch is pressed for more than 10 seconds, the RT30 shall enter Channel Select
mode.
5.3.3
RU Power/Mode Switch
This switch has three positions:
• Off – The unit is off, and battery power is completely disabled.
• On – The receiver is on, and the Beeper is enabled.
• Silent – The receiver is on, but the Beeper is disabled from announcing alarm conditions. Beep codes
• On – The receiver is on, and the Beeper is enabled.
• Silent – The receiver is on, but the Beeper is disabled from announcing alarm conditions. Beep codes
for auxiliary functions shall still be sent.