Справочник Пользователя для Indyme Solutions Inc CB529A

Скачать
Страница из 5
Technical Document 
CB529A Program & Install Instructions                                1                                                              P/N 430721-00 Rev C 
CB529A
CB529A Programming and Installation Instructions 
The CB529A is a special purpose, multi-function call box. It is designed for 
use as a director, shopper and/or external contact call box. The CB529A 
contains 4-inputs, each input can be configured for use as a normally 
opened or normally closed contact. The contacts can be configured 
individually or globally. The CB529A must be correctly configured and 
programmed to operate with external devices. Identify the quantity and types 
of circuits you will be using prior to beginning installation. 
Call Box Jumpers
The CB529A requires +3VDC to operate. Power 
can be supplied via 2-C size batteries or an 
external +12VDC power supply. Using JP201,
select the desired power source by placing the 
jumper over the two corresponding pins. 
Removing the jumper or placing it on one pin of 
JP201 will disable the call box. 
The CB529A has 4-inputs, each input has a jumper used to assign the circuit type, normally opened (NO) or 
normally closed (NC). Using the jumpers labeled, JP301- JP304, set the circuit type for each input. Placing a 
jumper over both pins on the right, or removing the jumper, assigns a normally opened input. Placing a jumper 
over both pins on the left assigns a normally closed input. (The picture at right 
indicates all inputs configured for normally opened inputs.) 
Call Box Programming
The CB529A uses a hierarchy based menu structure. Programming requires a 
series of button presses to access each menu. Using button-1 to SET, button-
A to RESET and the button-1 assurance LED,
 program the following menu 
options.
Enter Programming Menu
Press and hold the RESET button (approx. 8-sec) until the assurance LED blinks once. 
Press and hold the SET button (approx. 8-sec.) until the assurance LED blinks twice. 
Press and hold the RESET button (approx. 8-sec.) until the assurance LED blinks three times. 
Proceed to the desired menu. 
Menu-1: Address Programming
 -used to assign an alarm address to a call box. The address will 
define which message(s) are broadcast when the call box is activated. The valid address range is from 
001 to 999. Leading zeros are required. The default alarm for all call boxes is alarm-001.                   
(Example: Alarm-107) 
After entering the Programming Menu; 
Press the SET button once, RESET once. The assurance LED will flash once to confirm your 
entry. You are now in Menu-1. 
Enter your address as follows. 
ƒ Press 
the 
SET button once, RESET once to save. (1)
ƒ Press 
the 
RESET button once to represent the zero. (0)
ƒ Press 
the 
SET button seven times, RESET once to save. (7)
PRE-RELEASE