Справочник Пользователя для Indyme Solutions Inc CB529A

Скачать
Страница из 5
Technical Document 
CB529A Program & Install Instructions                                2                                                              P/N 430721-00 Rev C 
When the last digit is saved, the assurance LED will confirm your entry by flashing to indicate the digits 
entered. A zero is indicated by a long flash of approximately 1-second.  
Call box buttons-2-4 are automatically assigned the next consecutive alarm numbers. They cannot be 
programmed independently. 
Menu-3: Global Input Mode
 -used to assign operational characteristics to all inputs globally. The 
operational characteristics define how the call box will respond to button presses, input triggers and 
timing parameters.
After entering the Programming Menu; 
Press the SET button 3-times, RESET once to save.  
The assurance LED will flash three times to confirm your entry. You are now in Menu-3. 
Press the SET button <1--6> times to select the Operating Mode, RESET once to save.  
The assurance LED will flash to confirm your entry.
 
Menu-11: Individual Input Mode
 -used to assign operational characteristics to each input individually. 
The operational characteristics define how the call box will respond to button presses, input triggers 
and timing parameters.
After entering the Programming Menu; 
Press the SET button 11- times, RESET once to save.
The assurance LED will flash eleven times to confirm your entry. You are now in Menu-11. 
Press the SET button <1–4> times to select the input you are programming, RESET once to 
save. The assurance led will flash to confirm your entry. 
Press the SET button <1–4> times to select the Operating Mode, RESET once to save. 
The assurance LED will flash to confirm your input number, pause, then flash to confirm your 
Operating Mode entry. 
NOTE:
Operating Modes <5--6> are NOT valid for Individual Input Mode.  
When Operating Modes <5--6> are set globally, Individual Input Mode is disabled. 
Operating Modes 
Mode-1: Alarm Notify Non-Latching 
Basic alarm notification; compatible with “Shopper Call Box” alarm processing. 
When any INPUT is activated, an alarm SET is broadcast and the corresponding LED will flash 
according to “LED Sequence 1”. (Indicated below.) 
When the INPUT is deactivated, an alarm RESET is broadcast and the corresponding LED will turn off. 
Mode-2: Alarm Notify Latching 
Basic alarm notification, response required; 
When any INPUT is activated, an alarm SET is broadcast and the corresponding LED will flash 
according to “LED Sequence 1”. (Indicated below.)  
When the INPUT is deactivated, NO alarm RESET is broadcast. The corresponding LED will continue 
to flash until the front panel button is pressed.  
Responding user must press the front panel button corresponding to the active INPUT to broadcast an 
alarm RESET and turn off the LED. If a front panel button is pressed when the INPUT is not active, 
(non-alarm), an alarm RESET is broadcast. 
PRE-RELEASE