3.6.8.6 Diagnostics Screen
3.6.8.6.1
Power-Up Diagnostics Results
The Power-up Diagnostics Results screen is shown in 
. This screen shows the results of the most recent 
power-up diagnostics test.  Each time any of the navaid’s embedded processors is reset or powered up, it performs a 
series of internal diagnostic tests to verify its integrity.  The results of those tests are displayed on this screen for the 
RMS,  Monitors  and  Audio  Generators.  CPU  Functional  tests  are  instruction  and  data  fetches,  bit  operations,  and 
math  operations.  RAM  checks  are  extensive  tests  on  individual  bit  positions  of  all  RAM.  PROM  checks  are 
checksum  calculations  and  comparison  against  checksums  established  at  the  factory.  EEPROM  checks  are 
checksum  validations of data  held in EEPROM.  Green indications are  normal.  If a  module indicates a power-up 
diagnostic failure, it should be replaced. 
 
Depending on where in the startup process the fault is detected, failure of the monitor or audio generator will either 
stop servicing the watch dog or enter the failsafe shutdown loop.  
 
In the case of the audio generator, either case will result in no radiation.  
 
In the first case for monitor, communications would never be established, and the RMS would remove it from the 
LCU voting logic and force the outputs into the alarm state.  In the second case for the monitor, the monitor forces a 
hard alarm to the LCU and the RMS would remove it from LCU voting logic after the integrity tests failed. 
 
The RMS when failed does not enable the LCU and waits for the watchdog to reset and if the fault does not clear 
then the reset continues until the RMS is replaced. 
 