Model 1150A DVOR 
 
Rev. -  November, 2008 
 
This document contains proprietary information and such information may not be disclosed 
to others for any purposes without written permission from SELEX Sistemi Integrati Inc. 
3-75
3.8.10 Audio Generator CCA (1A3A2, 1A3A9)
Refer to 
and 
 for the indicators and controls on the Audio Generator CCA. 
 
Figure 3-71  Audio Generator Controls and Indicators 
 
Table 3-15  Audio Generator CCA (1A3A2, 1A3A9) Controls and Indicators 
TP0 
Ground 
TP1 
Carrier Amplifier Modulation. Audio signal sent to the Carrier Amplifier to modulate the carrier 
TP2 
Voice modulation (with identification) audio prior to summation with the reference signal 
TP3 
Oscilloscope synchronization signal at 30 Hz. 
CPU OK 
This LED when lit (GREEN) indicates that the Audio Generator processor is operating normally