Справочник Пользователя для Selex Sistemi Integrati Inc. VOR2

Скачать
Страница из 254
Model 1150A DVOR 
 
Rev. -  November, 2008 
 
This document contains proprietary information and such information may not be disclosed 
to others for any purposes without written permission from SELEX Sistemi Integrati Inc. 
4-1
4
STANDARDS AND TOLERANCES 
 
4.1 INTRODUCTION
  is  a  list  of  equipment  parameters,  their  standards,  and  their  limits.    In  the  Parameter  column,  each 
parameter  measured or adjusted is listed.  The paragraphs  of 
 and 
 that describe the procedures 
used to establish the values of the parameters are listed in the Reference Paragraph column.  In the Standard column 
are listed the optimum values of the parameters.  The Initial Tolerance column is the maximum possible deviation, 
above  or  below  the  standard  value,  when  the  DVOR  equipment  is  commissioned  initially  or  subsequent  to  any 
modification. The Operating Tolerance column is the possible deviation, above or below the standard value, when 
the DVOR equipment is in operation after the completion of commissioning activities.  
 
Table 4-1  Standards and Tolerances 
Parameter 
Standard 
Initial  
Tolerance 
Operating 
Tolerance 
Reference 
Paragraph 
a.  Antenna VSWR 
1.0:1 
1.2:1 
1.25:1
 
b.
Power Output 
 
 
 
(1) Carrier 
Value established 
by flight 
inspection 
20% of standard 
(-1dB) 
V50% of 
standard 
(-3dB)
 
6.2.2 (Operating) 
(2) Sideband  
For 30% AM 
Value established 
by flight inspection 
Standard, 
±2.0% 
(Modulation)
 
c.  Frequencies 
 
 
 
(1) Carrier 
Assigned Freq. 
Standard, 
±0.0005% 
Nominal, 
±0.001%
 
6.2.3 (Initial and 
Operating) 
(2) 9960 Hz 
9960 Hz 
±0.02% 
±0.02%
 
6.2.5 (Operating) 
(3) 30Hz Variable FM 
30 Hz 
±0.02% 
±0.02%
 
6.2.5 (Operating) 
(4) 30Hz Reference 
AM 
30 Hz 
±0.02% 
±0.02%
 
6.2.5 (Operating) 
(5) Ident 
1020 Hz 
±1 Hz 
±2 Hz 
6.2.11 (Initial and 
operating) 
d.
Modulation 
 
 
 
(1) 30 Hz 
30% 
±0.5% 
±2% 
6.2.4 (Operating) 
(2) 9960 Hz (AM) 
30% 
±0.5% 
±2% 
6.2.4 (Operating) 
(3) 9960Hz Deviation 
(FM) 
16:1 
±1 
±1
 
6.2.4 (Operating) 
(4) Ident 
8% 
±1% 
±2%
 
6.2.11 (Initial) 
  6.2.4 (Operating) 
e.  Reflected Powers 
 
 
 
(1) Reference VSWR 
1.0:1 
1.25:1 
1.25:1
 
6.2.6 (Operating) 
(2) Sideband VSWR 
1.0:1 
1.25:1 
1.25:1
 
6.2.6 (Operating) 
f. 
Monitor Alarms 
 
 
 
(1)  30  Hz  Modulation 
Low 
28%  
±.2% 
±1% 
6.2.4 (Operating) 
(2)  30  Hz  Modulation 
High 
32% 
±.2% 
±1% 
6.2.4 (Operating)