Model 1150A DVOR 
 
Rev. -  November, 2008 
 
This document contains proprietary information and such information may not be disclosed 
to others for any purposes without written permission from SELEX Sistemi Integrati Inc. 
6-7
l. 
Use  the  PMDT  to  display  RMS  >>  RMS  Data  >>  Power  Supply  Data,  AC  Input  Amps  and  verify  the 
reading is within 0.3 amps of DVM reading. 
m. 
If  not  within  0.3  amps  adjust  1A5A2  BCPS  R56  so  the  RMS  >>  RMS  Data  >>  Power  Supply  Data,  AC 
Input Amps is within 0.3 amps. 
n. 
Turn off TX 1 and TX 2 AC and DC circuit breakers. 
o. 
At the shelter circuit breaker panel turn off AC power for the VOR station. 
p. 
Remove the DVM and reconnect the AC line wire to the AC Monitor (1A6) TB3 position 1. 
q. 
Restore AC power to the VOR at the circuit breaker panel. 
r. 
Restore the VOR to the NORMAL STATE. 
 
6.4.1.3 Obstruction Light AC Voltage Alignment 
a. 
Use  a  Digital  Volt  Meter  (DVM)  configured  for  AC  voltage  to  measure  across  AC  Monitor  (1A6)  TB1 
position 1 and position 3.   
 
NOTE 
Terminal TB1-1 is normally connected to TB1-2 when a photo sensor is not used with the 
obstruction light.  When using a photo sensor the light opening must be covered with an 
opaque object in order to force the obstruction light to turn on. 
 
b. 
Use  the  PMDT  to  display  RMS  >>  RMS  Data  >>  Power  Supply  Data,  OB  Light  volts  and  verify  the 
reading is within 2 VAC of DVM measurement. 
c. 
If not  within 2 VAC adjust 1A5A1 BCPS R29 so the  RMS >> RMS Data >> Power Supply Data>> OB 
Light volts is within 1 VAC of DVM measurement. 
d. 
For single transmitter equipment skip to step h. 
e. 
Turn off Transmitter 2 AC and DC breakers while leaving Transmitter 2 AC and DC breakers on.  
f. 
Use  the  PMDT  to  display  RMS  >>  RMS  Data  >>  Power  Supply  Data,  OB  Light  volts  and  verify  the 
reading is within 2 VAC of DVM measurement. 
g. 
If  not  within  2  VAC  adjust  1A5A2  BCPS  R29  so  the  RMS>>RMS  Data>>  Power  Supply  Data>>  OB 
Light volts is within 2 VAC of DVM measurement. 
h. 
Restore the VOR to the NORMAL STATE. 
 
6.4.1.4 Obstruction Light AC Current Alignment 
a. 
Turn off AC and DC circuit breakers.  
b. 
At the shelter circuit breaker panel turn off AC power for the VOR station including obstruction lights. 
c. 
Disconnect the wire from the AC source to AC Monitor (1A6) TB1 position 2 (LINE). 
d. 
Connect  a  Digital  Volt  Meter  (DVM)  in  line  with  the  wire  from  AC  Monitor  (1A6)  TB1  position  2  (OB 
LITE, LINE). Set the DVM to measure AC current using a 10A scale.   
 
NOTE 
Terminal TB1-1 is normally connected to TB1-2 when a photo sensor is not used with the 
obstruction light.  When using a photo sensor the light opening must be covered with an 
opaque object in order to force the obstruction light to turn on. 
 
e. 
Disconnect any equipment connected to the front panel AC convenience outlet on the 1A7 Status Panel.  
f. 
Connect  a  Digital  Volt  Meter  (DVM)  in  line  with  the  wire  from  AC  Monitor  (1A6)  TB1  position  2  (OB 
LITE, LINE). Set the DVM to measure AC current using a 10A scale.   
g. 
Restore AC power to the VOR and obstruction light at the circuit breaker panel. 
h. 
Use  the  PMDT  to  display  RMS  >>  RMS  Data  >>  Power  Supply  Data,  OB  Light  Amps  and  verify  the 
reading is within 0.3 amps of DVM reading. 
i. 
If  not  within  0.3  amps  adjust  1A5A1  BCPS  R44  so  the  RMS  >>  RMS  Data  >>  Power  Supply  Data,  OB 
Light Amps is within 0.3 amps. 
j. 
For single equipment skip to step n. 
k. 
Turn off Transmitter 1 AC and DC breakers leaving Transmitter 2 circuit breakers on.