Справочник Пользователя для Selex Sistemi Integrati Inc. VOR2

Скачать
Страница из 254
Model 1150A DVOR 
 
Rev. -  November, 2008 
 
This document contains proprietary information and such information may not be disclosed 
to others for any purposes without written permission from SELEX Sistemi Integrati Inc. 
6-5
f. 
Verify that the modulation is within the tolerance of 
Table 4-1(d)(4)
.
g. 
Measure the Ident frequency and verify it is within the tolerance of 
Table 4-1(c)(5)
.
h. 
Turn on transmitter 2 by pointing and clicking the Tx 2 antenna button. 
i. 
Connect oscilloscope probe to Transmitter 2 Carrier Amplifier 1A5A4-P2. 
j. 
Measure the high and low peak voltages and calculate the modulation by the following relation:  
 
Emax - Emin 
% Ident Modulation = ---------------------- 
Emax + Emin 
 
k. 
Verify that the modulation is within the tolerance of 
Table 4-1(d)(4)
.
l. 
Measure the Ident frequency and verify it is within the tolerance of 
Table 4-1(c)(5)
.
m. 
Adjust Transmitters>> Configuration>> Reference and Voice Modulation to the previous settings. 
n. 
Select Transmitters>> Commands>> VOR Ident>> Normal. 
o. 
On the Monitors>> Data>> Integral screen, verify that the Ident is NORMAL. 
 
6.3 EQUIPMENT INSPECTION PROCEDURES 
6.3.1 Site Inspection
a. 
Check that the site is clear of any new obstructions or materials which could affect the normal operation of 
the DVOR system. 
b. 
Check the shelter, inside and out, for any sign of water filtration, damage, or other deterioration. 
c. 
Check the condition of the air conditioner, shelter lighting, obstruction lights, baseboard heaters, electrical 
outlets, lightening arrestors, etc. 
d. 
Check for and remove any debris, accumulation of snow (over 4 inches, 10 cm), or ice (over 0.5 inches, 1.5 
cm), on the field monitor antennas. 
e. 
Check  for  and  remove  any  accumulation  of  debris  or  snow  (over  1  foot,  30  cm)  on  the  counterpoise 
surface. 
 
6.3.2 Inspection of Transmission Antennas
a. 
Insure that both DVOR transmitters are turned off. 
b. 
The DVOR antennas are contained within fiberglass radomes. 
c. 
Inspect  the  mating  areas  of  the  radomes  where  the  radome  interfaces  with  the  radome  base  or  where  the 
radome  interfaces  with  the  antennas.    Check  for  any  signs  of  water  leakage  or  deterioration.    Repair  or 
replace as necessary. 
d. 
If  the  radome  shows  water  leakage,  remove  the  radome  and  inspect  the  antenna  for  any  signs  of 
deterioration  of  water  damage.  Replace  or  repair  the  radome  as  necessary.  Check  the  input  cables  and 
connectors for breaks, cracks or corrosion.  Check that the connectors are securely fastened, and inspect the 
remaining parts of the antenna for damage or signs of vermin infestation. 
e. 
Inspect the counterpoise for any signs of deterioration, paying special attention to the welded joints, bolted 
connections,  mesh,  etc.    Check  for  proper  electrical  connection  between  the  counterpoise  segments  and 
grounding  connections.  Corrosion  should  be  corrected  by  removing  rust  and  applying  paint  or  cold 
galvanizing spray. 
f. 
Remove any articles carried into the radome area and replace the antenna radome covers. 
 
6.3.3 Inspection of the Field Monitor Antenna
a. 
Inspect the condition of the field monitor antenna.  Make sure it is solidly mounted, and that all nuts and 
bolts are tightened. 
b. 
Check the ground wire connection to earth ground, tighten connections if necessary. 
c. 
Inspect the condition of the field monitor antenna coaxial cables for signs of cracks or breakage.  Replace if 
necessary.