INSTALLATION GUIDE
hidglobal.com
An ASSA ABLOY Group brand
© 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S.
and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
RKCL40E, RPKCL40E, RKCLB40E
SRD Model: RPKCL40E, RKCLB40E
iCLASS SE Biometric/iCLASS SE Display
E
Alternate Reader Assembly
The following steps reconfigure the reader assembly to
position the LCD Display component on the left side
of the assembly.
position the LCD Display component on the left side
of the assembly.
1. Disassemble the Reader.
• Remove the Reader from the backplate.
• Carefully unplug the ribbon cable from the module in the
back of the Reader.
• Carefully unplug the ribbon cable from the module in the
back of the Reader.
Caution: Do not pull on the
ribbon cable as this may damage the connection to the
Reader LCD Display
connector.
• Remove the LCD Display from the backplate.
• Gently pull the ribbon cable through the backplate.
• Remove the LCD Display from the backplate.
• Gently pull the ribbon cable through the backplate.
2. Reassemble with the LCD Display on the left side of the assembly.
• Rotate the backplate so that the large cutout for the power cable is on the left
• Gently route the ribbon cable back through the backplate slots, as shown below
• Plug the ribbon cable back into the module (back of Reader) and ensure module is fully
seated into the reader
• Attach the LCD Display to the backplate (this must be installed first, as the Reader will fit
slightly over the LCD Display)
• Attach the Reader to the backplate (power cable must be threaded through the large
square cutout on the backplate)
• Return to Section 2.
• Gently route the ribbon cable back through the backplate slots, as shown below
• Plug the ribbon cable back into the module (back of Reader) and ensure module is fully
seated into the reader
• Attach the LCD Display to the backplate (this must be installed first, as the Reader will fit
slightly over the LCD Display)
• Attach the Reader to the backplate (power cable must be threaded through the large
square cutout on the backplate)
• Return to Section 2.
Test card
Standard Configuration
Alternate Configuration
LCD Display Reader
LCD Display
Reader
Ribbon cable
Reader Backplate
Reader
LCD Display
Reader Backplate
Ribbon cable