SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
The procedures assume that the technical personnel are familiar with the test 
equipment used and can operate the equipment to produce the required inputs and 
obtain the required results (indications). Refer to the detailed operating procedures 
and descriptions of the HSD Maintenance Utility Program included in this section.
CAUTION:  
Only Authorized Technical Personnel, trained in general aviation 
workmanship, that have a basic understanding of SATCOM systems, 
should proceed with the Operational and Diagnostic test procedures 
presented in this manual.
CAUTION:  
Changes to some Menu functions may seriously degrade system 
operation.
Note:
This manual describes the basic maintenance utility program functions, 
menus, and reports required for the testing and fault isolation procedures 
presented in this section. Please consult EMS SATCOM support personnel 
before entering any unfamiliar menu selections not described in this manual.
Note:
Using a terminal emulation program, open a log file and save all test results 
for future reference and test records. This section includes detailed user 
instructions on opening and saving log files using the HSD maintenance utility 
program.
Note:
The procedures presented in this section aid the technical personnel in 
upgrading, maintaining, or troubleshooting an HSD system. Maintenance 
does not imply lubrication or adjustment activities.
REFERENCE INFORMATION
: Refer to the Outline and Installation drawings and the 
Interconnection diagrams presented in 
 for additional 
information.
(2) Test Setup Procedure
The test setup procedure is presented in Table 4–21. Refer to "Connection 
Requirements" on page 4-4 
for detailed connection of test equipment and operating 
instructions for the HSD maintenance utility program.
 Table 4–21. Test Setup Procedure
STEP
ACTION
0
Ensure that the HSD or HSD-X transceiver is neither powered up nor 
connected to a power source before proceeding.
0
If a remote access has not been installed: on the front panel of the HSD or 
HSD-X transceiver, remove the maintenance-port-connector cover.
0
Connect a cable to the HSD or HSD-X front-panel or remote maintenance 
port connector.
0
Connect the other end of the cable to a computer’s serial port. 
0
Open a log file to capture all test data.