Справочник Пользователя для EMS Technologies Canada Ltd. HSD-X

Скачать
Страница из 366
Page 4–52
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
(5) Configuration Parameters Verification
The system configuration parameters can now be verified. Verify and document using 
"Installation Checklist" on page D-1.
(a) Parameter Verification Procedure
For units operating control processor software versions 5.7 or earlier:
 1.
From Menu 3, select item ‘L’ (list EEPROM). The EEPROM listing appears 
on the screen. The EEPROM listing appears as shown in Figure 4–30.
 2.
From Menu 4, select item ‘Q’ (channel card forward IDs). Ensure the 
displayed Forward ID(s), for all channel cards, are correct.
For units operating control processor software versions 5.7 or later:
From Menu 3, select item ‘O’ (list ORT). The ORT listing appears on the 
screen, as shown in Figure 4–31. Verify that the correct system configuration 
parameters are listed in the ORT.
5.0
Remotes
(Optional—but 
recommended)
Remote Reset switch operation
Maintenance Port, remote access
Power and Fault LED indicators
6.0
RF Coax
Rx input cable loss from DLNA to HSD at BP12 and to the 
RFU at TPC1 (including splitter)
Tx output cable loss from HSD at MPC1 to DLNA
7.0
Antenna 
Connection
Antenna manufacturer and model
Multi-Control loopbacks installed from TP3E to TP1A and 
TP3F to TP1B (Stand-Alone Mode)
8.0
SDU
HSD to SDU interconnect wiring confirmed 
(Non-Stand-Alone modes)
 Table 4–24. HSD Electrical Verification
STEP
Item Checked
Verification Description