2.3.2 BDLC
PD
 assembly Power
The BDLC
PD
 assembly uses a standard 120 VAC
power cord. Plug this cord to the rear power out-
let shown in Figure 4 and Figure 5.
To check or install a fuse:
1.  Open the slide-out fuse drawer located below
the power connector by using a fine bladed
screwdriver or a knife blade and gently pry
open.
2.  Hold the fuse support in one hand and with
the other, lift the center plastic retainer until
it releases the fuse sliding base.
3.  Replace or install a 250V, 2A fuse.
4.  To complete the procedure, push the sliding
fuse base until it snaps under the retainer.
5.  Re-insert the fuse drawer in its housing and
push until it is fully seated and closed.
When ready to apply power, use the ON-OFF
toggle power switch adjacent to the power con-
nector.
Figure 5 - BDLC
PD
’s rear connection, switch, and fuse
2.4 Antenna
2.4.1 Overview
Paragon
PD
 commonly uses three antennas (one
transmit and two receive) unless a duplexer is
used with one of the receive antennas; then only
two antennas would be needed. They should be
mounted according to any guidelines supplied
with the antennas. For antennas placement and
spacing, consult System Engineering.
2.4.2  Cabling and Connection
1-  Route good quality 50-ohm double-shielded
coaxial cable(s) (e.g. RG-214 or Heliax) from
the selected antenna position(s) to the Para-
gon
PD
 Radio assembly.
2-  Terminate the RX-1 and RX-2 cable ends at
the Receiver modules rear position with an
N-type connector.
3-  Similarly, terminate the TX cable end at the
Power Amp’s module rear position with an
N-type connector.
Caution:
When terminating RF cables use brand-name
crimping tools (such as AMP, Jensen,
CrimpMaster, etc…) of the correct size for
the cable and type of connector used.
Common pliers are NOT acceptable.
2.5  Completing the physical
Installation.
Paragon
PD
 products are factory-configured to
user’s requirements and are shipped ready to run.
After new installations:
  Re-check that all connections are secure on
radio and BDLC
PD
 assemblies (antennas, PC,
power cords etc.)
  Check that fuses are inserted.
  Turn both BDLC
PD
 and radio power ON.
You are now ready to check for normal operation
(as per paragraph 2.6) and to run the Dataradio
Windows Radio Installation Software (WinRIS)
program for testing or trouble-shooting.
Any change(s) to the settings must be done via
files saved on diskette and loaded into the unit
using the WinRIS program.
Employer u niquement  av ec
un  fusible de 250 V
Use only with  a  250 V fuse
ON-OFF
Switch
120VAC
Connector
Fuse
Slide-out
Drawer