Advanced use 
 
 
 
 51 
Calibrate the scanner 
The bar code scanning device in the All-in-One is a model 5180 imager that was manufactured by 
Honeywell Imaging and Mobility. To understand the imager better or to modify settings, refer to the 
5X80 Engine Series 5X10/5X80 User's Guide that can be downloaded at www.honeywell.com/aidc. 
The 5X10/5X80 User's Guide contains configuration bar codes that can be used to customize the 
desired allowable bar codes and to change options and settings on the imager. 
Reset the standard product defaults 
If you are not sure what programming options are in your imager, or if you have changed some 
options and want the factory settings restored, scan the Standard Product Default Settings bar 
code, below. 
 
Figure 10-10
 Standard product default settings bar code 
 
 
NOTE:
 The light bar will briefly go out to indicate that the scan was completed successfully. 
 
Update firmware through USB 
1. 
Connect the All-in-One to a computer with a USB cable.  
2. 
Open the HP sp400 Series Configuration Software. See "
."  
3. 
Select the Update tab. 
There are four types of firmware update files: 
 
Firmware: the main program running on the All-in-One 
 
FPGA: the processor configuration 
 
Imager: the program running on the bar code scanner module 
 
Communication: the program running on the wireless communication module 
4. 
In the File boxes, enter the names of the update files. You can use the Browse button to 
navigate to the update files. 
 
NOTE:
 All of the update file names must have an “.hhp” extension. 
 
5. 
Press the Write to Device button to begin the update process. 
6. 
If you are doing a firmware or FPGA update, a dialog box instructing you to restart the All-in-
One appears:  
a. 
Click OK to dismiss the dialog box. 
b. 
Press the green Power button on the All-in-One and hold for three seconds to turn the 
device off.  
c. 
After the All-in-One has turned off, restart it by pressing the Power button for one second. 
d. 
When the connection status indicates that the device is connected again, restart the update 
process by clicking the Write To Device button. 
uncing that the update has b
7. 
A dialog box anno
een successful or has failed appears. If the 
update failed, try performing the update again before contacting support personnel.