ADCP-75-124 • Issue B • April 2002 • Section 5: Maintenance
Page 5-15
©
 2002, ADC Telecommunications, Inc.
Figure 5-1. Air Filter Removal and Replacement
4. Gently
 tap the filter against your hand to dislodge the dirt. If necessary, use compressed air
or
 a vacuum cleaner to remove the dirt. 
5. Re-install
  the  filter  in  the  door  and  tighten  the  hex  nuts  that  secure  the  left  and  right
brackets
 to the door. 
5.3
Host Unit Fan Replacement Procedure
The
  HU  is  equipped  with  two  cooling  fans  which  are  located  on  the  right  side  of  the  HU
enclosure.
 The cooling fans blow cool air into the enclosure. Heated air is exhausted through the
vent
 openings on the left side of the enclosure. Replacement of the fans requires that the HU be
turned
 off for a short period of time. Use the following procedure to remove and replace the HU
cooling
 fans: 
1. Before
 working on the HU or handling a fan, slip on an Electro-Static Discharge (ESD)
wrist
 strap and connect the ground wire to an earth ground source. Wear the ESD wrist
strap
 while completing each section of the fan installation procedure. 
2. Notify
 the NOC or alarm monitoring system operator that the system is going offline. 
3. Place
 the HU On/Off switch in the OFF position (press O). 
4. Remove
 the six flat-head screws (requires TORX screwdriver with T10 bit) that secure the
fan/grill
  assembly  to  the  right  side  of  the  HU  enclosure  as  shown  in 
  Save
screws
 for reuse. 
Warning:
  Electronic  components  can  be damaged  by  static  electrical  discharge. To prevent
ESD
 damage, always wear an ESD wrist strap when working on the HU, STM, or LPA and
when
 handling electronic components. 
LOOSEN HEX NUTS ON BOTH
SIDES OF AIR FILTER
LIFT AIR FILTER UP AND
AWAY FROM DOOR
16983-A