Справочник Пользователя для Microwave Radio Communications LLC STATXU064T1CK

Скачать
Страница из 98
 Routine Operation
3-9
STRATA TX Operator’s Guide/Tech Ref Manual
  
Each of the controls, indicators, and connectors are described in 
more detail in the following paragraphs. Controls, indicators, and 
connectors contained on the ACU are shown in 
.
ACU AC INPUT Connector
  The AC INPUT  connector 
mounted on the rear panel of the unit provides external AC 
power to the unit.
ACU POWER Switch  
The front panel POWER switch controls 
application of DC power to the DC OUTPUT connector.  When 
the switch is set to I (on), DC power is present at the DC 
OUTPUT
 connector. When set to (off), no output DC power is 
present at the DC OUTPUT connector.  
ACU Power LED  
The  power LED is on when the POWER 
switch is set to I (on), indicating DC power is available at the DC 
OUTPUT
 connector.  The indicator is off when the POWER 
switch is set to 0 (off).
ACU DC OUTPUT Connector  
 The DC OUTPUT connector 
mounted on the front panel of the unit provides +28 VDC power 
to the TCU and/or TXU. 
ACU FUSE  
The fuse provides overload protection for AC input 
power.
Topic
Page
Figure 3-4: ACU Controls, Indicators, and Connectors
3.2.4
STRATA Standard Remote Control Panel 
Controls, Indicators, and Connectors
For controls, indicators, and connectors contained on the 
optional Standard Remote Control Panel, refer to the STRATA 
Remote Control Panel Operator’s Guide, Document number 
400489.
3.2.5
STRATA Aircraft Remote Control Panel 
Controls, Indicators, and Connectors
For controls, indicators, and connectors contained on the 
optional STRATA Aircraft Remote Control Panel, refer to the 
STRATA Aircraft Remote Control Panel Operator’s Guide, 
Document number 400490.     
OUTPUT
OUTPUT
<  >
<  >
DC
DC
FUSE
POWER 
Switch
Power
LED
DC OUTPUT 
Connector
AC INPUT 
Connector