Short Range Programmer VRT—User Guide 
 
Page  11 
P/N 52806T100 Rev 1 April 2003 
  AMCO Automated Systems
 
Using Read Meter Index Mode
 
 
This mode reads the meter index (meter count). It will display whole units 
only. (For pre-divider/sub-count values use Read Pre-divider mode.) 
 
1.  Press the MODE button repeatedly until the display shows the “Enter 
Read Meter Index” screen. 
 
2.  Acquire the transponder serial number. 
 
•  Acquire serial number either: (a) by using the Find mode first or 
(b) by manually entering the serial number in this mode. 
 
3. 
Press one of the two INT (interrogate) buttons. 
 
•  If the interrogation is successful, the SRP will display the 
transponder serial number, the current meter index value and the 
tamper indicator, if applicable (as shown below): 
•  Any TAMPER indication that appears will not appear again on 
the next interrogation. (Tampers are automatically “cleared” after 
interrogation.) 
 
•  If the interrogation is NOT successful, the screen will display the 
“CARRIER NOT DETECTED” message (indicating no signal 
from transponder) or “RECEIVE DATA ERROR” (indicating radio 
signal interference). These messages display for 2 seconds, 
during which time the SRP will not interrogate.. 
 
 
4.  If the interrogation is NOT successful, move the SRP to a slightly 
different position relative to the transponder (closer, farther away, or 
to one side) and interrogate again. 
 
•  Radio waves can bounce off of, or be absorbed or deflected by, 
various materials (especially metals) which can create slight 
differences in signal strength from one spot to another.   
 
 
 
READ  METER  INDEX 
 Serial No..  ??????? 
 
READ  METER  INDEX 
 Serial No..  ??????? 
INDEX NO.. 00001234 
TAMPER