Справочник Пользователя для Digital Monitoring Products Inc PC0096
Digital Monitoring Products
XT30/XT50 Installation Guide
14
InstallatIon
Ethernet Connector J1
14.1 Description
The Ethernet Connector (J1) is available on the Network version and connects directly to an Ethernet
network using a standard patch cable.
14.2 Ethernet LEDs
The two LEDs, located on the left side of the J1 Ethernet Connector,
indicate network operation. The top, Link LED is a steady green light
when an ethernet cable is connected. The bottom, Activity LED
flashes yellow to indicate messages are being received or transmitted.
Reset Jumpers J16
15.1 Description
The reset header is located just above the terminal strip on the right side of the circuit board and is used
to reset the XT30/XT50 microprocessor. To reset the panel when first installing the system, install the reset
jumper before applying power to the panel. After connecting the AC and battery, remove the reset jumper.
To reset the panel while the system is operational, for example, prior to reprogramming, install the reset
To reset the panel while the system is operational, for example, prior to reprogramming, install the reset
jumper without powering down the system. Remove the reset jumper after one or two seconds.
After resetting the panel, begin programming within 30 minutes. If you wait longer than 30 minutes, you
After resetting the panel, begin programming within 30 minutes. If you wait longer than 30 minutes, you
must reset the panel again.
XT30/XT50 Panel
J3
Phone Line
Outputs
J11
1
2
3
4
J1
Ethernet
J20
Wireless
Antenna
connection
J7 RJ
Supervision
J24 Celllular
header for
263G
connection
J19 Celllular
Antenna
connection
65555
Momentarily
place the Reset
jumper over both
of the J16 pins to
reset the panel.
J16
Reset
J18
Load
RED
Programming
J8
Figure 9: Panel Showing the Reset Jumper Wires
Flash Load Jumper J18
16.1 Description
To update the XT30/50 panel with a new software version (ru file), place jumpers on the Reset (J16) and
Load (J18) headers. Connect a DMP 399 Cable from the J8 Programming Header to a laptop PC containing
the ru file. Then, remove the jumper from the Reset (J16) header while leaving the Load (J18) jumper in
place.
After the software version is updated, return the jumper to Reset (J16), remove the Load (J18) jumper and
After the software version is updated, return the jumper to Reset (J16), remove the Load (J18) jumper and
the 399 cable. Then remove Reset (J16) jumper to resume normal panel operation.
Figure 8: J1 Connector and LEDs
J1
Ethernet
Link LED