Справочник Пользователя для Digital Monitoring Products Inc PC0193
DESCRIPTION
Figure 1: 1136 Wireless
Remote Chime
1
PROGRAM THE PANEL
The 1136 is programmed in the panel as an output. Refer to the
panel programming guide as needed.
Note: For panels with Version 171 firmware or below, there must
Note: For panels with Version 171 firmware or below, there must
be a wireless keypad programmed into the system for the 1136 to
function properly.
1. In
OUTPUT SETUP, enter the OUTPUT number. For the
first 1136 added to a system, use the following output
numbers:
• XT30/XT50 systems use output 34
• XTLplus systems use output 54
• XR150/XR550 systems use output 453
• XTLplus systems use output 54
• XR150/XR550 systems use output 453
Additional 1136s can be programmed into any other
available output slots.
2. Enter the
OUTPUT NAME.
3. Enter the eight-digit
SERIAL# and press CMD.
4. Enter the
SUPRVSN TIME (supervision time) and press
CMD.
5. Press
CMD when TRIP WITH PANEL BELL displays.
6. Press the back arrow when
OUTPUT SETUP displays.
7. Press
CMD until STOP displays and then press any top
row select key or area.
2
SELECT A LOCATION
Since the 1136 does not have a visible survey LED, use a wireless
device with a survey LED to confirm communication with the
wireless receiver or panel. DMP recommends using an 1106
Wireless Transmitter. This process ensures that the outlet you
choose is in a good location.
Check the Location Using a Survey LED
1. Open the wireless device and hold it over the standard
110VAC wall outlet you would like to use.
2. Press the tamper switch to send data to the wireless
receiver and see if communication is confirmed or faulty.
Confirmed: If communication is confirmed, the LED
blinks immediately on and immediately off for each
press or release of the tamper switch.
Faulty: If communication is faulty, the survey LED
Faulty: If communication is faulty, the survey LED
remains on for about 8 seconds or flashes multiple
times in quick succession.
3. Relocate the device to a different outlet or relocate the
wireless receiver until the survey LED confirms clear
communication.
The 1136 Wireless Remote Chime
is a multi-function sounder that
plugs directly into a standard
110VAC wall outlet.
The 1136 provides extra
annunciation in installations that
benefit from a louder keypad
chime, or small multi-family
applications where no keypad
is installed and the system is
controlled from an app.
The 1136 annunciates Chimes
(Zone Monitor), as well as
Entry Delay, Exit Delay and
Alarm messages.
Compatibility
All DMP 1100 Series Wireless
Receivers and burglary
panels. See the last page for
compatibility details.
Once you have located an outlet with confirmed communication
to the panel, plug in the 1136. See Figure 1.
3
PLUG IN THE 1136
1136 WIRELESS REMOTE CHIME
Installation Guide