Manual iSense Lumen series
Power Inserter
When the installation location of the products is clear, the location of Power Inserters needs to be defined.
There is a maximum number of Renos units that can be connected to one Power Inserter, depending on which
technologies are used and the number of add-ons that are in use. The table below shows the amount of Power
Inserters needed for each hardware configuration. 
Cable conditions: a CAT 5E with a maximum cable length of 75 meter or a CAT 6 with a maximum cable length
of 100 meter.
Technologies in use
#units / PI 230V #units / PI 115V
RF
5
5
RF + RFID
3
3
RF + MD
5
4
RF + 2 SD's
4
4
RF + MD + 2 SD's
4
3
RF + RFID + MD
3
3
RF + RFID + MD + 2 SD's 3
*
3
*
* If the RFID units are operated monostatically, only 2 gates can be connected to a single power inserter.
Index:
RF = Radio Frequency 8.2 MHz
RFID = RAIN Radio Frequency Identification (~900 MHz)
MD = Metal Detection
2 SD's = 2 connected smart deactivators
Nedap Power Inserters
Please note that you can only use a Nedap Power Inserter (Power-over-Ethernet) to power Renos
systems. It is not possible to use generic Power-over-Ethernet switches or stand-alone inserters.