A P P E N D I X  
INTERACTIONS 
   
F10 System – Proximity to Deactivation Units 
The table below lists minimum distances where Counterpoint IX or D11 Deactivators can be 
located away from a F10 system antenna.  
Deactivators do not affect the F10 system performance.  
However, in 4 and 6 Mode, if any F10 system is located inside a 1.8m [6ft] radius from the 
deactivator, false alarms may occur because the deactivator “sees” the system.  
It is not possible to slave a deactivator to a system with Strata-based electronics. 
  Note: The deactivator will intermittently alarm as it sees the F10 pulsing, these alarms will occur on average 
every 30 seconds. 
 
 
Distance to F10 System 
MODELS 
(all with pad) 
Up to 1.8m (6.0')  
> 1.8m (6.0') 
CP IX/D11  
4 Mode 
Deactivator Phantoms 
(see note
No Interactions 
CP IX/D11  
5 Mode 
No Interactions 
No Interactions