Справочник Пользователя для Checkpoint Systems Inc. EVOLVEF10

Скачать
Страница из 71
F10 Installation Manual 
                         Rev. *60          
 
68 of 71
 
A P P E N D I X  
DETECTION  PERFORMANCE 
F10, 2 Meter System  
The diagram and corresponding table show the expected FCC and CE detection heights for the 
F10, 2 meter system, using a 410EP tag in three different orientations (flat, side, and front carry).  
 
Note:  These detection heights are specified for a “clean” environment.  If noise is present, detection 
performance will be reduced. 
 
Detection Heights
 
for a 410EP tag with TX = 31 and RX = 31: 
 
 
A (cm) 
B (cm) 
C (cm) 
D (cm) 
E (cm) 
F (cm) 
Flat 
100 
120 
140 
140 
120 
100 
Side 
110 
125 
110 
110 
125 
110 
Front 
85 
100 
110 
110 
100 
85 
 
  Note:   Detection heights are measured from the bottom of the antenna assembly, not from the finished floor 
height.  F10 system antennas are buried 7.6cm (3”) into the floor. 
 
The following Detection Patterns are observed for the F10, 2 meter system. Note that the 
orientation of the tag is important as it alters the expected detection height.