Chapter 3 - Operation and AdministrationBTS Menu
Chapter 3: Operation and Administration
BTS Menu
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BreezeCOMPACT System Manual
BreezeCOMPACT System Manual
59
3.5.2.5.2
DSCP
The DSCP value of management traffic. 
The range is 0-63. 
The default is 0.
3.5.3
Unit Control
The Unit Control menu enables various general control functions, such as resetting the BTS, managing the software 
versions of the BTS and uploading/downloading configuration backup files.
The Unit Control menu includes the following options:
3.5.3.1
Monitor Inactivity Timeout
The Monitor Inactivity Timeout (in minutes) parameter determines the amount of inactive time following which the unit 
automatically exits the Monitor program.
The timeout duration can range from 0 to 60 minutes. 0 means no inactivity timeout.
The default value is 10 minutes.
3.5.3.2
SW Version Control
The BTS can contain two software versions:
Operational: Each time the BTS resets it reboots using the version defined as Operational.
Shadow: Normally the Shadow version is the backup version. Each time a new software file is downloaded to the BTS, 
it is stored as a Shadow version, replacing the previous Shadow Version.
The typical process of upgrading to a new software version includes the following steps:
1
Download the new software file to the BTS. It is stored as the Shadow version.
2
Reset and run the BTS from its Shadow version. Note that at this stage, if a reset occurs, the BTS returns to the previous 
Operational version.
3
If you want to continue using the new version, swap the Shadow and Operational versions. The new (currently running) 
version is now defined as Operational, and is used each time the BTS reboots. The previous version is defined now as 
Shadow.