Справочник Пользователя для Honeywell International Inc. KSN770

Скачать
Страница из 248
Draft
Page 3-1
6 Dec 2012
34-70-06
SYSTEM INSTALLATION MANUAL
066-01204 / 066-01213
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SECTION III - SYSTEM INTERCONNECT
3.1
Introduction
Section III contains information relative to KSN 7xx Safety Navigator interconnection diagrams, options 
available to the system planner, and specific electrical characteristics of the various interfaces where 
applicable. Each paragraph in this section contains the installation wiring diagrams for that section.
For information regarding the compatibility of equipment not listed in this manual, the installing agency 
must contact Bendix/King customer service at www.BendixKing.com.
Section III is divided into major sections by interface type or major topic. Each major section describes in 
detail the specifications for particular types of interfaces connecting to the KSN 7xx.
3.2
Standard Interface Definitions
Unless otherwise stated, the following interface definitions will apply.
3.2.1
Discrete Input
Refer to Table 3-1 for the discrete input states.
3.2.2
Discrete Output
Unless otherwise stated, the following interface definitions will apply. Unless otherwise stated, all 
outputs may be used as high current discrete outputs.
3.2.2.1
High Current
Refer to Table 3-2 for the high current discrete output states.
Table 3-1.  Discrete Input States
State
Voltage Upper Limit
Voltage Lower Limit
Comment
Open/High
N/A
14 VDC for aircraft power
24.8 VDC
7.0 VCD for aircraft power
12.4 volts
Impedance is >230 kilohms 
to GND
Low
3.0 VDC
0 VDC
Impedance is <95
 
ohms to 
GND
Table 3-2.  High Current Discrete Output States
State
Voltage Upper Limit
Sinking Current
Comment
Active
2.0 VDC
0 to 250 mA DC
-
Inactive
N/A
N/A
Open collector
Draft as of 10/15/2012