AT+ MAXSK =<num ><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
num: 1~32, default 32. maxima TCP connection;
When configure as TCP/Server, HF-a11x support maxime 32 TCP connections. If not require so
much connection, user can resetting this parameters.
much connection, user can resetting this parameters.
4.2.2.25. AT+EPHY
Function: Open/Close ETH interface;
Format:
Format:
Set
Operation
AT+ EPHY=<on/off><CR>
+ok<CR>< LF ><CR>< LF >
+ok<CR>< LF ><CR>< LF >
Parameters:
On/off
Off: Close Ethernet port function;
On: Open Ethernet port function;
On: Open Ethernet port function;
Close module’s Ethernet port function can reduce the power consumption. The default setting for
HF-A11x is close Ethernet port function.
HF-A11x is close Ethernet port function.
4.2.2.26. AT+RELD
Function: Restore to factory default setting;
Format:
Format:
AT+ RELD<CR>
+ok=rebooting…<CR>< LF ><CR>< LF >
+ok=rebooting…<CR>< LF ><CR>< LF >
This command restores the module to factory default setting, and then re-starts the module.
4.2.2.27. AT+Z
Function:
Re-start
module;
Format:
AT+ Z<CR>
4.2.2.28. AT+MID
Function: Query module ID information;
Format:
Format:
Query
Operation
AT+MID<CR>
+ok=<module_id><CR>< LF ><CR>< LF >
+ok=<module_id><CR>< LF ><CR>< LF >
Parameters:
module_id: Module ID information;
A11-yymmddnnnn “yymmdd” date; “nnnn” serial number;