APPENDIX A: QUESTIONS AND ANSWERS 
Q1: How to configure transparent serial port application (TCP protocol) 
with two HF-A11x modules? 
¾  Network structure as below figure: 
„  Module 1#  Setting: 
—  Works as AP mode;                                        --See “Mode Selection Page” 
—  LAN IP address: 10.10.100.254;                      --See “AP Interface Setting Page”  
—  Network Protocal:TCP/Server, Port ID: 8899;  -- See “Application Setting Page”  
(Module default setting); 
„  Module 2#  Setting: 
—  Works as STA mode;                                   --See “Mode Selection Page” 
—  WAN connection type: DHCP or Static IP (For this example:10.10.100.100) 
                                                                              --See “STA Interface Setting Page”                                        
—  Network Protocal:TCP/Client, Port ID: 8899; Application IP address: Module 1#’s 
LAN IP address (10.10.100.254);                          -- See “Application Setting Page” 
—  Notes: When module 2# works as STA mode, module’s WiFi interface works as 
WAN port. Module’s WAN IP address and LAN IP address shall be setting different 
segment. So, module 2#’s LAN IP address must change to other segment; (For 
this sample, we change to 10.10.99.254);     --See “AP Interface Setting Page” 
 
Figure 42.  Configure Transparent Serial Port Connection (TCP) 
Q2: Where to Set HF-A11x Module LAN IP and WAN IP through Web Page 
¾  HF-A11x Wireless LAN IP address setting see “AP Interface Setting Page” as below Figure, 
 
Figure 43.  Module LAN IP Setting 
¾  HF-A11x Wireless WAN IP address setting see “STA Interface Setting Page” as below 
Figure, User can set WAN connection type to DHCP and STATIC IP.