Figure 44. Module WAN IP Setting
Q3: How to configure transparent serial port application (UDP protocol)
with two HF-A11x modules?
with two HF-A11x modules?
¾ Network structure as below figure:
Module 1# Setting:
Works as AP mode; --See “Mode Selection Page”
LAN IP address: 10.10.100.254; --See “AP Interface Setting Page”
Network Protocal:UDP, Port ID: 8899; Application IP address:10.10.100.100;
LAN IP address: 10.10.100.254; --See “AP Interface Setting Page”
Network Protocal:UDP, Port ID: 8899; Application IP address:10.10.100.100;
-- See “Application Setting Page”
Module 2# Setting:
Works as STA mode; --See “Mode Selection Page”
WAN connection type: Static IP (10.10.100.100)
--See “STA Interface Setting Page”
Network Protocal:UDP, Port ID: 8899; Application IP address: Module 1#’s LAN IP
WAN connection type: Static IP (10.10.100.100)
--See “STA Interface Setting Page”
Network Protocal:UDP, Port ID: 8899; Application IP address: Module 1#’s LAN IP
address (10.10.100.254); -- See “Application Setting Page”
LAN IP address: 10.10.99.254 (Different net segment with WAN port)
--See “AP Interface Setting Page”
Figure 45. Configure Transparent Serial Port Connection (UDP)
Q4: Where to set HF-A11x module network protocol (TCP/UDP)?
¾ HF-A11x network protocol setting see “Application Setting Page” as below Figure,
Protocol: TCP Server
Only Port ID required: 8899 (Default)