Справочник Пользователя для Andrew Wireless Innovations Group RPT-MOR701

Скачать
Страница из 79
User’s manual for Remote Unit MOR701B Power
M0069A0A.doc
Id.-No 151154
Page 61
23-June-99
figure 9-5 Position of dummy battery backup module
9.7 Replacement of the duplexer
This description is valid for the one channel configuration of the Repeater only. For different
configurations refer to the assembly guide for the Repeater.
Remove the semi-rigid cables which connect the DL Output with the feed forward amplifier
by loosening the SMA connector. Use a torque wrench. Then remove the semi-rigid cable
from the mother board.
It is recommended not to remove the amplifier which is mounted on the backside of the
duplexer. A new duplexer will be delivered with a premounted amplifier.
The cables have to be connected as shown below.
figure 9-6 Cable configuration of the duplexers
dummy battery backup module
G0850M1