Справочник Пользователя для Andrew Wireless Innovations Group RPT-MOR701

Скачать
Страница из 79
User’s manual for Remote Unit MOR701B Power
M0069A0A.doc
Id.-No 151154
Page 62
23-June-99
Unscrew the four counter sunk screws M3 at the connector panel of the Repeater. See figure
9-7 Connector panel layout.
figure 9-7 Connector panel layout
9.8 Replacement of RF modules
To remove the RF modules, disconnect the SMA connectors by means of a torque wrench.
If the Repeater is equipped with TDMA modules, the external filter on top of the modules
must be dismounted beforehand. The external filter box covers two of the socket head cap
screws the TDMA module is fixed with.
Unscrew the socket head cap screw on top of the external filter box, pull the box carefully off
and continue the dismounting procedure as described below.
Unscrew six socket head cap screws by means of a hex socket key.
Pull carefully by means of the mounting strap, fixed on the module (see figure 9-8 Top view
of an RF module) and take off the module.
G0850Z0