7.2 Setting of operational parameters
Attenuation of the Repeater can be set manually by means of rotary switches, frequency can
be set locally or  remotely.
There are three different possibilities to set the operational parameters:
-manual settings by means of rotary switches
-local control via RS232 interface and PC
-remote control via modem
7.2.1 Manual settings by means of rotary switches
The manual mode allows the user to set the required channels and attenuation by means of
rotary switches. With a small screwdriver, which fits through the long holes of the RF
modules, the values can be adjusted by turning the switch carefully to the desired position.
Note:
To enable manual settings of parameters the mode switch (DIP-Switch 1)
has to be changed from OFF to ON.
The DIP-Switch is mounted on the control module, located on the left side of the Repeater.
figure 7-2 Position of the DIP-Switch 1
DIP-Switch 1