3 Installation 
 
ID No: 161692 
PRELIMINARY 
Page 17
 
3.1.4  Pole Mounting Procedures  
 
The following figure illustrates the two pole mounting options:  
back-to-back (left) and two systems (right). 
 
 
 
 
figure 3-5 Pole mounted systems 
 
•  Before starting the mounting procedure, check the pole diameter of the pole to 
which the units will be installed; then, cut the thread-bolts (see table 3-3 
Components of pole mounting kits
, pos. 5) to the required length according to the 
following table, which also states the appropriate cable bridge lengths: 
 
Pole-diameter 
(mm) 
100 110 120
130
140
150
160
170
180 190 200
Length of Thread-
Bolt (mm) 
216 226 236
246
256
266
276
286
296 306 317
Length of cable 
bridge (mm) 
(back-to-back) 
800 2000 
Length of cable 
bridge (mm) 
(for 2 systems) 
800 2000 
table 3-2 Required length of thread-bolts and cable bridge