4 Commissioning 
 
ID No: 161692 
PRELIMINARY 
Page 25
 
4 COMMISSIONING 
4.1 GENERAL 
 
Read the health and safety warnings in chapter 1.2 Health and Safety Warnings and 
observe the following step-by-step procedure.  
•  Do not operate the Node C without terminating the antenna connectors. The 
antenna connectors may be terminated by connecting them to their respective 
antennas or to a dummy load. 
•  Only qualified personnel should carry out the electrical, mechanical, 
commissioning, and maintenance activities that require the unit to be powered 
on when open.  
•  When opening the Node C or interface box do not damage the warranty labels 
on the internal devices. The warranty is void if the seals are broken. 
 
To open the cabinet of the Interface Unit, first remove 
the front cover plate by loosening the four M5 socket 
head cap screws (circle-marked in figure to the left). 
Do not remove those screws. When they are 
loosened the front cover plate can be taken off. 
 
To open the housing, unscrew the three M5 socket 
head cap screws (captive) of the top cover of the 
Interface Unit. 
)
 Note: 
Do not forget to reinstall the front 
cover afterwards to ensure safe 
operation.
  
 
)
  Note: Before closing the Interface 
Unit, make sure that the mains power 
switch inside is set to On:
 
 
 
 
figure 4-1 Front and top cover screws 
figure 4-2 Position of mains power switch 
Three top 
cover screws 
Mains power switch