F8L10D-N LoRa Module User Manual
                                                                                                                     
Page  23  of  33 
 
Add:11th Floor, A-06 Area, No.370, Chengyi Street, Jimei, Xiamen, Fujian, China. 
                                    Tel:  +86 592-5907276                              Fax:+86 592-5912735 
 
4.3 LoRa Parameters Setting 
4.3.1 Serial Com Set 
It can set the Serial Com port parameters, such as baud rate, data bit, check bit and 
stop bit 
The default value: baud rate is 115200. Data bit is 8. Check bit is N, and stop bit is 1。
 
4.3.2 Work Mode 
There are three work modes,
”TRNS”,“AT” and “API”. 
TRNS --
Transparent Data to LoRa. The “Transparent Address” must be set。 
AT      --AT operating mode, refer to 
AT Command Manual”, which is usually used for 
parameter configuration and manual testing. 
API    --API operating mode, refer to 
API Command Manual”, whose payload’s length 
must be less than 100 Bytes. 
Default value is TRNS. 
 
4.3.3 ID 
        The ID of LoRa Module, id range is 0~65535 
4.3.4 Work Frequency 
        The data transmission frequency of module. The work frequency bands are divided 
into low frequency band (525MHz below) and high frequency band (525MHz above)  for 
different modules. Typical operating frequency bands contain 410M ~ 441MHz, 470M ~ 
510MHz,  850  ~  950MHz,  etc.,  1000KHz  for  a  channel.  Different  application  areas  have 
different frequency band restrictions, so what we should do is to adjust the value to local 
conditions. 
The  default  value  for  the  low-band  hardware  module  is  433,  and  the  default  for  the 
high-band module is 868. 
4.3.5 Airy Rate 
The Airy Rate is the speed of data transferring. The bigger the Bit Rate, the faster of