Справочник Пользователя для etatronix GmbH EXM10RXLINK

Скачать
Страница из 10
exm10Rx
Integration Manual
1 Electrical Specification
1.1 Operating Conditions
Parameter
Min Typ Max Unit
Output voltage
1,3
-
-
20
V
Output current
1,2
-
-
2.7
A
Ambient temperature
-25
-
70
C
Standby current
3
-
tbd.
-
mA
Data transmission frequency
-
2
-
MHz
1
In case of a connected battery, output current and voltage depend on actual charge state. The module
works in CC/CV mode.
2
Output current and voltage limitation can be tailored to specific load and battery requirements.
3
Receiver module not connected with power transmitter, BMS active.
1.2 Interface
Parameter
Min Typ Max
Unit
Low level digital interface
1
-0.1
-
0.6
V
High level digital interface
1
2.7
-
3.4
V
Maximum voltage at PG
1,2
-
-
4.2
V
Maximum current PG
1
-
-
10
mA
Output Capacity
-
-
440
µF
Battery Fuse Rating
-
T7
-
A
Battery Fuse Melting Integral
-
8.7
-
A
2
Sec
1
Internal limiting series resistor: 330 Ω.
2
Voltage at PG-pin shall not exceed the output voltage.
1.3 Compliance
Regulation
Description
EN 55011 class B EMI regulation for home equipment
exm10Rx-Integration Manual-Draft-01.pdf
August 2018
/ 10