Trouble shooting 
 
 
InkMachines 
TPS-500
 
Rev 3.0 / 2018-05-25 
32 (27) 
 
 
The Foot switch  
Start with using the OK-button on the Control panel to see if the Tattoo machine is working ok. 
 
Instruction  
If  the  Footswitch  still  not 
functioning  with  the  Tattoo 
machine 
 
1. Check that the Foot switch is paired 
with  the  Main  unit.  The  running 
symbol  will  be  shown  on  the  display 
when the foot switch is pressed down. 
 
Go to 2.  
 
2. PAIR FOOTSWITCH from the settings menu. 
Go to 3. 
 
3. Check that the Footswitch battery is placed with the positive 
terminal  (+)  facing  down,  see  Exchange  of  foot  switch  battery 
on page 27. 
Go to 4. 
 
4.  Check  that  the  Foot  switch  is  cleaned  and  that  there  is  no 
left dirt that could affect the function. 
 
Go to 5. 
 
5. Exchange battery, it may be discharged or bad. 
Something 
wrong 
with 
the 
footswitch,  Contact  InkMachines 
for  further  instructions,  see 
.