13.1 Status
 
When the X75 is first accessed using a WEB browser the Controller Status page 
shown below is displayed.
 
Figure 11 - Status WEB Page (typical)
 
The following describes the function of the different parts of the applet with the 
exception of FACTORY SETTINGS which is reserved for UNIPOWER use.
 
At the top is the site name.  This can be changed in the installation applet.
 
Next is the main system bus voltage.  Note that this will always show as an unsigned 
value even in systems that have a negative voltage with respect to chassis ground.
 
Next to the system voltage is an indicator of the state of the system.  The various 
possible indicators are as follows:
FLT
  Indicates that the system is in float mode without any temperature 
compensation.
TC
 
Indicates that the system is in float mode with temperature compensation 
applied.
CHG
  The system is bulk charging the batteries.
EQ
 
The system is equalizing or boosting the battery voltage.
BD
 
The system is in battery discharge.
TST
  The system is performing a battery test.