2. Installing Stratus ESG
2.1.
Unpacking/inspection requirements
When unpacking Stratus ESG, visually inspect for any damage to the unit or missing
components. If damage or missing parts are present, contact Appareo.
components. If damage or missing parts are present, contact Appareo.
2.2.
Limitations for installation
This article meets the minimum performance and quality control standards required by a
technical standard order (TSO). If you are installing this article on or in a specific type or class of
aircraft, you must obtain separate approval for installation.
technical standard order (TSO). If you are installing this article on or in a specific type or class of
aircraft, you must obtain separate approval for installation.
The following limitations should be taken into consideration when installing Stratus ESG.
Aircraft
Stratus ESG may not be acceptable for installation on all aircraft makes and models.
Cooling air
Stratus ESG does not have an air cooling duct. Do not install Stratus ESG near a heat source.
An alternate method of cooling is required if the unit must be installed near a heat source.
An alternate method of cooling is required if the unit must be installed near a heat source.
2.3.
Backplate assembly and rack installation
Refer to Stratus ESG Installation and Wiring Drawings (601837-000024) to assemble the
mounting rack with the hardware specified in Table 10. Mount the rack to the aircraft using the
six holes on the side of the rack with the hardware specified in Table 11.
mounting rack with the hardware specified in Table 10. Mount the rack to the aircraft using the
six holes on the side of the rack with the hardware specified in Table 11.
Refer to Section 1.8 for dimensions and weight information.
NOTE: For an optimal fit, mounting brackets may be required, but are not supplied. If additional
brackets are needed, they should be fabricated for each individual installation.
brackets are needed, they should be fabricated for each individual installation.
NOTE: Assure that the unit is supported in the back. This may require additional support.