Technical Information 
 
 
23 
4.3.12 
X13 
– 
Ethernet interface 
The Ethernet interface is on Ethernet connection X13. Ethernet connection X13 
comprises 2 Ethernet interfaces, Ethernet interface X13a and the 3-port switch 
X13b. 
Property 
Value 
Type 
4x RJ45 
shielded 
Ethernet 
10/100 Mbit/s full/half duplex auto 
sense; automatic detection of 
"crossover" or "patch" wiring. 
Table 26: Technical Information – Ethernet interface 
4.3.13 
X14 
– 
Power supply 
Connection of the power supply takes place using connector X14. 
Property 
Value 
Operating voltage 
12 V … 24 V DC (±20%) 
Power consumption 
< 15 W under full load 
< 6 W under reduced operation (idle) 
IP rating 
Housing IP30, connector IP20  
Table 27: Technical Information – Power supply 
Terminal 
Signal 
Description 
Ground 
Power supply 
Table 28: Terminal X14 – Power supply 
Wire 
Cross-section 
Nominal cross-section 
2.5 mm² 
Rigid 
0.2 
– 
2.5 mm² 
Flexible 
0.2 
– 
2.5 mm² 
Flexible with end sleeve 
0.25 
– 
2.5 mm² 
Table 29: Terminal X14 – Permissible wire cross-sections 
According to the requirement of IEC 61851 (Ed. 3 CDV), voltages (ELV) between 
EVSE and EV must be isolated from the grid using transformers that comply with 
the requirements according to IEC 61558-1 and -2-4. This must apply to the supply-
ing power supply unit in the charging station. Use limited power source (LPS) acc. 
UL/IEC 60950-1 or UL/IEC 62368-1 only.