Technical Information 
LSX 
 
 
26 
Property 
Value 
Signal 
Voltage monitor 
Execution 
Contact input (to GND) 
Power supply 
internal pull-up resistor  
10 kOhm at 5 V DC 
LOW level 
0 … 1 V DC 
HIGH level 
3.5 … 5 V DC 
External voltage resistance 
-5 … 30 V DC 
Table 38: Technical Information – Connection charging point 1 – Voltage monitor 
Property 
Value 
Signal 
Proximity 
Execution 
Analogue input 
Voltage range 
0 … 5 V DC 
Accuracy 
+/-5% 
Resolution 
10 bit 
External voltage resistance 
0 … 5 V DC or max. 100 mA 
Table 39: Technical Information – Connection charging point 1 – Proximity 
Property 
Value 
Signal 
Contactor 
Execution 
Open drain output (to GND) 
Continuous current 
max. 1 A 
Short-time current (<1 s) 
5 A 
Electric strength 
30 V 
Table 40: Technical Information – Connection charging point 1 – Contactor 
Property 
Value 
Signal 
Operating current trigger 
Execution 
Open drain output (to GND) 
Continuous current 
max. 1 A 
Short-time current (<1 s) 
5 A 
Electric strength 
30 V 
Table 41: Technical Information – Connection charging point 1 – Operating current trigger