Справочник Пользователя для Transition Networks E-100BTX-FX-05

Скачать
Страница из 7
E-100BTX-FX-05
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 
Operation 
-- Continued
Pause Control 
The Pause feature can improve network performance by allowing one end of
the link to signal the other to discontinue frame transmission for a set period
of time to relieve buffer congestion.
NOTE: If the Pause feature is present on ALL network devices attached to the
media converter(s), enable the Pause feature on the media converter(s).
Otherwise, disable the Pause feature
Link Pass-Through
The Link Pass-Through feature allows the media converter to monitor both the
fiber and copper RX (receive) ports for loss of signal. In the event of a loss of
an RX signal (1), the media converter will automatically disable the TX
(transmit) signal (2), thus, “passing through” the link loss (3). The far-end
device is automatically notified of the link loss (4), which prevents the loss of
valuable data unknowingly transmitted over an invalid link. 
Far-End Fault
When a fault occurs on an incoming fiber link (1), the media converter
transmits a Far-End Fault signal on the outgoing fiber link (2). In addition the
Far-End Fault signal also activates the Link Pass-Through, which, in turn,
disables the link on the copper portion of the network (3) and (4).
3
1
Local
Media
Converter
Remote
Media
Converter
Near-End
Device
Far-End
Device
original fault on the
Ethernet copper link
remote converter disables
the Ethernet copper link
local converter sends a 
loss signal over the fiber link
2
fiber link is still valid
4
Far-End Fault
signal is sent
Media
Converter A
Media
Converter B
Near-End
Device
Far-End
Device
original fault
on the fiber link
media converter B
disables the copper link
media converter A
disables the copper link
3
4
2
1
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
7
Cable Specifications -- continued
Extended temperature models -- continued
E-100BTX-FX-05(100HT)
1310Tx/1550Rx nm single mode
E-100BTX-FX-05(101HT)
1550Tx/1310Rx nm single mode
Fiber-optic Transmitter Power:
min: -14.0 dBm
max:-8.0 dBm
Fiber-optic Receiver Sensitivity:
min: -33.0 dBm
max: -3.0 dBm
Link Budget:
19.0 dB
Standard models
E-100BTX-FX-05
1300 nm multimode
Fiber Optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity:
min: -30.0 dBm
max: -14.0 dBm
Link Budget:
11.0 dB
E-100BTX-FX-05(SC)
1300 nm multimode
Fiber Optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity:
min: -30.0 dBm
max: -14.0 dBm
Link Budget:
11.0 dB
E-100BTX-FX-05(MT)
1300 nm multimode
Fiber Optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity:
min: -33.5 dBm
max: -14.0 dBm
Link Budget:
14.5 dB
E-100BTX-FX-05(SM)
1310 nm single mode
Fiber-optic Transmitter Power:
min: -15.0 dBm
max: -8.0 dBm
Fiber-optic Receiver Sensitivity:
min: -31.0 dBm
max: -8.0 dBm
Link Budget:
16.0 dB
E-100BTX-FX-05(SMLC)
1310 nm single mode
Fiber-optic Transmitter Power:
min: -15.2 dBm
max: -8.0 dBm
Fiber-optic Receiver Sensitivity:
min: -32.5 dBm
max: -3.0 dBm
Link Budget:
17.3 dB
E-100BTX-FX-05(LH)
1310 nm single mode
Fiber-optic Transmitter Power:
min: -8.0 dBm
max: -2.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Link Budget:
26.0 dB
E-100BTX-FX-05(XL)
1310 nm single mode
E-100BTX-FX-05(LW)
1550 nm single mode
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: 0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Link Budget:
29.0 dB
The fiber optic transmitters on this device meet Class I Laser safety requirements
per IEC-825/CDRH standards and comply with 21 CFR1040.10 and
21CFR1040.11.