TECHNICAL SPECIFICATIONS
SYSTEM MODEL NUMBERS
COMPONENT MODEL NUMBERS
ELECTRICAL
Input Voltage
18 to 32 VAC; 24 VAC nominal
22 to 27 VDC; 24 VDC nominal
22 to 27 VDC; 24 VDC nominal
Input Power
24 VAC
23 VA nominal (without heater);
73 VA nominal (with heater)
73 VA nominal (with heater)
24 VDC
0.7 A nominal (without heater)
Fuse 1.25
A
Auxiliary Outputs
2
Alarm Inputs
7
GENERAL
Construction
Back Box and Lower Dome Type 316L stainless steel
Bubble Polycarbonate,
Bubble Polycarbonate,
0.090-inch
thick
Light Attenuation
1 F-stop (smoked); zero light loss (clear)
V-Band
Type 316L stainless steel
Pressure Relief
Brass
Schrader Valve
Brass
Connector
Nickel-plated steel
Mounting
1.5-inch NPT, threaded
Pressurization
Valve
Schrader
Pressure
8 psig (55 kPa) (not factory pressurized)
Pressure Relief
10 psig (69 kPa)
Operating Temperature
(Assumes no wind chill factor; for detailed
test conditions, contact Pelco)
test conditions, contact Pelco)
Maximum
140°F (60°C) absolute maximum; 122°F
(50°C) sustained maximum
(50°C) sustained maximum
Minimum
–60°F (–51.11°C) absolute minimum;
minimal icing at sustained minimum of –50°F
(–45°C); prevents icing at sustained minimum
of –40°F (–40°C); de-ices 0.1 inch (2.5 mm)
within 3 hours after power-up
minimal icing at sustained minimum of –50°F
(–45°C); prevents icing at sustained minimum
of –40°F (–40°C); de-ices 0.1 inch (2.5 mm)
within 3 hours after power-up
Weight (approximate)
Unit
Shipping
Back Box
10.2 lb (4.6 kg)
13 lb (5.9 kg)
Lower Dome
3.3 lb (1.5 kg)
7 lb (3.2 kg)
CERTIFICATIONS/RATINGS
• CE, Class B
• FCC, Class B
• UL/cUL Listed
• C-Tick
• S Mark for Argentina
• Meets NEMA Type 6P and IP67 standards
• FCC, Class B
• UL/cUL Listed
• C-Tick
• S Mark for Argentina
• Meets NEMA Type 6P and IP67 standards
OPTIONAL ACCESSORIES
IPS-CABLE
Remote monitor cable and software kit
IPS-RDPE-2
†
Remote data port
EH8000RKIT
Dry nitrogen recharging kit (cannot be refilled)
TXB Series
†
Translator boards for AD Manchester, Hernis,
Bosch
Bosch
®
(Philips, Burle), TASS, and NTCIP
protocols
FS85011A
†
Fiber transmitter sends one unidirectional
composite video channel and one
bidirectional data channel over one optical
fiber. Available in multimode and single-mode
versions
composite video channel and one
bidirectional data channel over one optical
fiber. Available in multimode and single-mode
versions
Mounts
IDM4012SS (stainless steel, wall),
IWM Series (wall), MRCA (ceiling),
PP4348 (parapet roof), and
PP350/PP351 (parapet wall/roof)
IWM Series (wall), MRCA (ceiling),
PP4348 (parapet roof), and
PP350/PP351 (parapet wall/roof)
†
If TXB or FS85011A boards are installed, it is not possible to upgrade system
operating software through the remote data port (IPS-RDPE-2).
Back Box Type
Lower
Dome
29X Day/Night
†
36X Day/Night
†
Environmental Pendant, Pressurized
Smoked
SD429-PRE0
SD436-PRE0
Clear
SD429-PRE1
SD436-PRE1
Environmental Pendant, Pressurized
Fiber Optic Feedthrough, Single-Mode
Fiber Optic Feedthrough, Single-Mode
Smoked
SD429-PRSE0
SD436-PRSE0
Clear
SD429-PRSE1
SD436-PRSE1
Environmental Pendant, Pressurized
Fiber Optic Feedthrough, Multimode
Fiber Optic Feedthrough, Multimode
Smoked
SD429-PRME0
SD436-PRME0
Clear
SD429-PRME1
SD436-PRME1
Pelco, the Pelco logo, and other trademarks associated with Pelco products referred
to in this publication are trademarks of Pelco, Inc. or its affiliates. ONVIF and the
ONVIF logo are trademarks of ONVIF Inc. All other product names and
services are the property of their respective companies.
Product specifications and availability are subject to change without notice.
©Copyright 2012, Pelco, Inc. All rights reserved.
Back Box
Lower Dome
Dome Drive*
BB4-PR-E
Environmental pendant, gray,
pressurized
pressurized
BB4-PRS-E
Environmental pendant, gray,
pressurized, fiber optic
feedthrough, single-mode
pressurized, fiber optic
feedthrough, single-mode
BB4-PRM-E
Environmental pendant, gray,
pressurized, fiber optic
feedthrough, multimode
pressurized, fiber optic
feedthrough, multimode
LD53PR-0
Lower dome with smoked bubble
LD53PR-1
Lower dome with clear bubble
DD429
Day/night (NTSC) camera (29X)
DD436
Day/night (NTSC) camera (36X)
DD5-FM
†
Removable, fixed mount bracket only
(camera and lens not included);
interchangeable with all Spectra IV dome
drives
(camera and lens not included);
interchangeable with all Spectra IV dome
drives
*For PAL and CCIR models add “-X” suffix to part number (for example: SD436-PRSE0-X or DD429-X)
†
To order a fixed mount system, refer to the component models above and select a back box model, a lower dome model, and the DD5-FM dome drive.
DD5-FM accepts camera and lens combinations including a BNC connector up to 12.70 x 6.99 x 6.99 cm (5.00" D x 2.75" W x 2.75" H).
DD5-FM accepts camera and lens combinations including a BNC connector up to 12.70 x 6.99 x 6.99 cm (5.00" D x 2.75" W x 2.75" H).