Справочник Пользователя для ZyXEL 202H 91-003-194003B

Модели
91-003-194003B
Скачать
Страница из 375
P-202H Plus v2 User’s Guide
313
Chapter 34 SA Monitor
The following table describes the fields in this menu.
Table 105   Menu 27.2 SA Monitor
FIELD
DESCRIPTION
#
This is the security  index number.
Name
This field displays the identification name for this VPN policy. This name is unique for 
each connection where the secure gateway IP address is a public static IP address. 
When the secure gateway IP address is 0.0.0.0 (as discussed in the last chapter), there 
may be different connections using this same VPN rule. In this case, the name is followed 
by the remote IP address as configured in Menu 27.1.1. – IPSec Setup. Individual 
connections using the same VPN rule may be terminated without affecting other 
connections using the same rule.
Encap.
This field displays Tunnel mode or Transport mode. See previous for discussion.
IPSec 
ALgorithm
This field displays the security protocols used for an SA. ESP provides confidentiality and 
integrity of data by encrypting the data and encapsulating it into IP packets. Encryption 
methods include 56-bit DES and 168-bit 3DESNULL denotes a tunnel without 
encryption.
An incoming SA may have an AH in addition to ESP. The Authentication Header provides 
strong integrity and authentication by adding authentication information to IP packets. 
This authentication information is calculated using header and payload data in the IP 
packet. This provides an additional level of security. AH choices are MD5 (default  - 128 
bits) and SHA -1(160 bits).
Both AH and ESP increase ZyXEL Device processing requirements and communications 
latency (delay).
Select 
Command
Press [SPACE BAR] to choose from RefreshDisconnect or None and then press 
[ENTER]. You must select a connection in the next field when you choose the 
Disconnect command. Refresh displays current active VPN connections. None allows 
you to jump to the “Press ENTER to Confirm…” prompt.
Select 
Connection
Type the VPN connection index number that you want to disconnect and then press 
[ENTER].
When you have completed this menu, press [ENTER] at the prompt “Press ENTER to Confirm…” to 
save your configuration, or press [ESC] at any time to cancel.