Chapter 11. SAN Connections and Configuration 
439
Draft Document for Review January 29, 2013 12:52 pm
8068ch11-SAN Config.fm
��
If the Microsoft Windows clustered system is rebuilt or restored from a backup, hosts must 
log off and then log back on to any previously connected iSCSI targets that are supplied 
from the system.
��
If the host application uses SCSI 3 Persistent Reservation, you must run only a single 
iSCSI session.
��
Running with multiple iSCSI sessions is not supported for applications using Microsoft 
2003 MSCS and Microsoft 2008 Failover clustering over an iSCSI interface; you must run 
only a single session in these situations.
11.3.4  iSCSI Multipath Connectivity
You can choose from several technologies to improve the availability of iSCSI by using 
multiple network paths. Multipathing requires a software layer above the iSCSI layer to make 
sense of the multiple physical paths between the initiator and target and to manage them 
appropriately.
Within the IBM Flex System Enterprise Chassis I/O modules 1+2 will be populated by 
Ethernet switches, these will allow iSCSI connectivity between a compute node and the IBM 
Flex System V7000 Storage Node. It is important to configure for switch redundancy by using 
iSCSI multipathing device driver software on the compute node host operating system. At the 
IBM Flex System V7000 Storage Node canisters both iSCSI Ethernet ports should be used.
In Figure 11-1 on page 434 it can be seen that NW 1 on each node canister is connected to 
Switch 1 and Switch 2. When configuring for iSCSI connectivity as shown in Figure 11-5, port 
2 is represented by the link to Switch 1 and port 3 is represented by the link to Switch 2 
across both canisters.
Figure 11-5   iSCSI ports 2 and 3 linking to switches in IBM Flex System Enterprise Chassis
At the host 4 paths can be configured to the IBM Flex System V7000 Storage Node using 
each of the 2 Ethernet ports from each of the storage node canisters. In Figure 11-6 on 
page 440
 the example shows that both switches are used with separate networks or subnets, 
each communicating with a storage node canister and a compute node.