IBM Flex System V7000 Storage Node Introduction and Implementation Guide
Figure 11-6 iSCSI redundancy using both Ethernet switches
11.3.5 Configuring Multiple iSCSI Host Links
This section will show how to configure the IBM Flex System V7000 Storage Node canisters
for multiple connections to a x240 compute node running MS Windows. The example will
create the configuration as shown in Figure 11-6, the x240 compute node has two Ethernet
adapter ports which are already configured with IP addresses. This example does not take
into account of network planning required or configuration on the Ethernet switch or TCP/IP
network being used. It is recommended that a form of access limitation is implemented
across the TCP/IP network such as use of VLAN and network security, the example below
does not include these details.
for multiple connections to a x240 compute node running MS Windows. The example will
create the configuration as shown in Figure 11-6, the x240 compute node has two Ethernet
adapter ports which are already configured with IP addresses. This example does not take
into account of network planning required or configuration on the Ethernet switch or TCP/IP
network being used. It is recommended that a form of access limitation is implemented
across the TCP/IP network such as use of VLAN and network security, the example below
does not include these details.
Refer to 6.2.2, “Create an iSCSI attached host” on page 259 for details on how to define an
iSCSI host on theIBM Flex System V7000 Storage Node.
iSCSI host on theIBM Flex System V7000 Storage Node.
Figure 11-7 on page 441 shows the iSCSI network view of the IBM Flex System V7000
Storage Node configuration GUI. From here the IQN can be seen and where IP address for
each canister can be set:
Storage Node configuration GUI. From here the IQN can be seen and where IP address for
each canister can be set:
1. Navigation pane to present view Node_ID Settings Network
2. Canister select option
3. IP address of Port 2 and Port 3 to be changed
4. Node and IQN used by the host when initiating the connection
Table 11-1 on page 441 shows the IP configuration settings for each iSCSI port on both
canisters, as described earlier are attached to Ethernet switches in IBM Flex System
Enterprise Chassis I/O Module ports 1 and 2.
canisters, as described earlier are attached to Ethernet switches in IBM Flex System
Enterprise Chassis I/O Module ports 1 and 2.