4. Check the FC switch zoning.
5. Install the 2145 host attachment support package, 
6. Install and configure the Subsystem Device Driver Path Control Module (SDDPCM).
7. Run cfgmgr or reboot the compute node to discover and configure the IBM Flex System 
V7000 Storage Node volumes.
Checking HBAs in the Compute Node
You can display the availability of installed host adapters by using the command lsdev -Cc 
adapter
. In Example 12-4 the HBA adapters are shown as fcs0 and fcs1.
Example 12-4   
# lsdev -Cc adapter | grep fcs
fcs0    Available 05-00 Dual Port 8Gb FC Mezzanine Card (7710322577107501) 
fcs1    Available 05-01 Dual Port 8Gb FC Mezzanine Card (7710322577107501) 
Check HBA Settings
Some settings on the HBAs differing from the default are recommended, for example, both 
fast fail and dynamic tracking should be enabled. To check these parameters issue the 
following command to the FC SCSI I/O Controller Protocol Device of each adapter as show in 
Example 12-5. From this example we can see that the settings are as they should be.
Example 12-5   Check HBA settings
# lsattr -El fscsi0                                                
attach       switch    How this adapter is CONNECTED         False 
dyntrk       yes 
      Dynamic Tracking of FC Devices        True  
fc_err_recov fast_fail
 FC Fabric Event Error RECOVERY Policy True  
scsi_id      0x10e00   Adapter SCSI ID                       False 
sw_fc_class  3         FC Class for Fabric                   True  
# lsattr -El fscsi1                                                
attach       switch    How this adapter is CONNECTED         False 
dyntrk       yes
       Dynamic Tracking of FC Devices        True  
fc_err_recov fast_fail
 FC Fabric Event Error RECOVERY Policy True  
scsi_id      0x10e00   Adapter SCSI ID                       False 
sw_fc_class  3         FC Class for Fabric                   True  
If one of these settings required changing the chdev command would be used, for example, to 
enable fast fail on fcs0 FC SCSI I/O Controller Protocol Device issue command:
chdev -l fscsi0 -a fc_err_recov=fast_fail
12.5.2  Operating system versions and maintenance levels
The following section details the current support information. It is vital that the websites that 
listed are checked regularly for any updates.
Presently, the only FC HBA supported on the p260 and p460 compute nodes is the IBM Flex 
System FC3172 2-port 8Gb FC Adapter, refer to SSIC to verify supported configurations:
See IBM ServerProven® website for the latest information about the specific versions and 
service packs that are supported: