a Flex System V7000 Storage Node canister using the Flex System V7000 Storage Node
service GUI.
service GUI.
1. Open the CMM and navigate to the chassis map. The chassis map displayed by the CMM
provides a graphical view of the IBM Flex System Enterprise Chassis components. Using
the mouse, locate the node that you want to power off, as shown in Figure 13-48.
the mouse, locate the node that you want to power off, as shown in Figure 13-48.
Figure 13-48 MM chassis map - powering on and off individual node canister
2. Click the node to display the Actions menu.
3. In the Actions menu click Power Off. (Controller will shutdown OS).
13.13.5 Powering on a node using the CMM
Use this procedure when it is necessary to power on the IBM Flex System V7000 Storage
Node using the CMM, as shown in Figure 13-48.
Node using the CMM, as shown in Figure 13-48.
1. Open the CMM and navigate to the chassis map. The chassis map displayed by the CMM
provides a graphical view of the Flex chassis components.
2. Using the mouse, locate the node that you want to power on.
3. Click the node to display the Actions menu.
4. In the Actions menu click Power On.
Attention: This operation can result in permanent loss of data on storage volumes or
loss of access to the volumes, Use the storage management user interface provided by
the storage node to power off the storage system or individual storage controllers. Only
continue if the service procedures have directed the use of this CMM power control
operation.
loss of access to the volumes, Use the storage management user interface provided by
the storage node to power off the storage system or individual storage controllers. Only
continue if the service procedures have directed the use of this CMM power control
operation.