8068AppA-CLI.fm
Draft Document for Review January 29, 2013 12:52 pm
586
 
IBM Flex System V7000 Storage Node Introduction and Implementation Guide
IBM_4939:FlexSystem_V7000:admin>mkfcmap -source Volume_FC_T_S1 -target Volume_FC_S -name FCMAP_rev_1 -copyrate 50
FlashCopy Mapping, id [1], successfully created
IBM_4939:FlexSystem_V7000:admin>mkfcmap -source Volume_FC_T_S1  -target Volume_FC_T1 -name FCMAP_2 -copyrate 50
FlashCopy Mapping, id [2], successfully created
IBM_4939:FlexSystem_V7000:admin>lsfcmap
id name        source_vdisk_id source_vdisk_name target_vdisk_id target_vdisk_name group_id group_name status         
progress copy_rate clean_progress incremental partner_FC_id partner_FC_name restoring start_time rc_controlled
0  FCMAP_1     5               Volume_FC_S       8               Volume_FC_T_S1                        idle_or_copied 0        
50        100            off         1             FCMAP_rev_1     no                   no
1  FCMAP_rev_1 8               Volume_FC_T_S1    5               Volume_FC_S                           idle_or_copied 0        
50        100            off         0             FCMAP_1         no                   no
2  FCMAP_2     8               Volume_FC_T_S1    7               Volume_FC_T1                          idle_or_copied 0        
50        100            off                                       no                   no
IBM_4939:FlexSystem_V7000:admin>startfcmap -prep FCMAP_1
IBM_4939:FlexSystem_V7000:admin>lsfcmap
id name        source_vdisk_id source_vdisk_name target_vdisk_id target_vdisk_name group_id group_name status         
progress copy_rate clean_progress incremental partner_FC_id partner_FC_name restoring start_time   rc_controlled
0  FCMAP_1     5               Volume_FC_S       8               Volume_FC_T_S1                        copying        0        
50        100            off         1             FCMAP_rev_1     no        111006160239 no
1  FCMAP_rev_1 8               Volume_FC_T_S1    5               Volume_FC_S                           idle_or_copied 0        
50        100            off         0             FCMAP_1         no                     no
2  FCMAP_2     8               Volume_FC_T_S1    7               Volume_FC_T1                          idle_or_copied 0        
50        100            off                                       no                     no
IBM_4939:FlexSystem_V7000:admin>startfcmap -prep FCMAP_2
IBM_4939:FlexSystem_V7000:admin>lsfcmap
id name        source_vdisk_id source_vdisk_name target_vdisk_id target_vdisk_name group_id group_name status         
progress copy_rate clean_progress incremental partner_FC_id partner_FC_name restoring start_time   rc_controlled
0  FCMAP_1     5               Volume_FC_S       8               Volume_FC_T_S1                        copying        3        
50        96             off         1             FCMAP_rev_1     no        111006160239 no
1  FCMAP_rev_1 8               Volume_FC_T_S1    5               Volume_FC_S                           idle_or_copied 0        
50        100            off         0             FCMAP_1         no                     no
2  FCMAP_2     8               Volume_FC_T_S1    7               Volume_FC_T1                          copying        0        
50        100            off                                       no        111006160359 no
IBM_4939:FlexSystem_V7000:admin>startfcmap -prep FCMAP_rev_1
CMMVC6298E The command failed because a target VDisk has dependent FlashCopy mappings.
IBM_4939:FlexSystem_V7000:admin>startfcmap -prep -restore FCMAP_rev_1
IBM_4939:FlexSystem_V7000:admin>lsfcmap
id name        source_vdisk_id source_vdisk_name target_vdisk_id target_vdisk_name group_id group_name status  progress 
copy_rate clean_progress incremental partner_FC_id partner_FC_name restoring start_time   rc_controlled
0  FCMAP_1     5               Volume_FC_S       8               Volume_FC_T_S1                        copying 18       
50        81             off         1             FCMAP_rev_1     no        111006160239 no
1  FCMAP_rev_1 8               Volume_FC_T_S1    5               Volume_FC_S                           copying 81       
50        18             off         0             FCMAP_1         yes       111006161024 no
2  FCMAP_2     8               Volume_FC_T_S1    7               Volume_FC_T1                          copying 14       
50        100            off                                       no        111006160359 no
Modifying Global Mirror Delay for testing
As described in 9.3, “Remote Copy” on page 380, a delay can be simulated on Global Mirror 
links. This feature is an advanced feature only available in the CLI. Example A-10 shows you 
how to add a delay to the Global Mirror connection.
Example: A-10   Add Global Mirror Delay
IBM_4939:FlexSystem_V7000:admin>lssystem
id 0000020061614FFC
name FlexSystem_V7000
.
console_IP 10.18.228.200:443