Appendix A. CLI Setup and Configuration 
587
Draft Document for Review January 29, 2013 12:52 pm
8068AppA-CLI.fm
id_alias 0000020061614FFC
gm_link_tolerance 300
gm_inter_cluster_delay_simulation 0
gm_intra_cluster_delay_simulation 0
gm_max_host_delay 5
.
tier generic_hdd
tier_capacity 5.45TB
tier_free_capacity 2.10TB
has_nas_key no
layer storage
rc_buffer_size 48
IBM_4939:FlexSystem_V7000:admin>lssystem
id 0000020061614FFC
name FlexSystem_V7000
gm_inter_cluster_delay_simulation 0
gm_intra_cluster_delay_simulation 20
gm_max_host_delay 5
.
IBM_4939:FlexSystem_V7000:admin>chsystem -gminterdelaysimulation 20
IBM_4939:FlexSystem_V7000:admin>lssystem
id 0000020061614FFC
name FlexSystem_V7000
.
gm_inter_cluster_delay_simulation 20
gm_intra_cluster_delay_simulation 20
gm_max_host_delay 5
.
For more details on the various commands and their usage, as well as the use of the 
command line interface itself; refer to 
Command-Line Interface User's Guide GC27-2287-03
 
located in the Info Center of the IBM Flex System V7000 Storage Node at:
Author comment - 
This is where the FlexV700 GUI sends us; need to watch for an update to be added 
here or the link to change. Also need to watch for any possible document # changes as this is the V7000 