Справочник Пользователя для Mitsubishi Electric MSZ-FH35VE-E1

Скачать
Страница из 38
11
WIRELESS REMOTE CONTROLLER
MSZ-FH25VE  MSZ-FH35VE
MICROPROCESSOR CONTROL
9
NOTE
: Last setting will be stored after the unit is turned OFF with the remote controller. Indoor unit receive the signal of the 
remote controller with beeps.
Signal transmitting section
Operation display section
Temperature buttons
OPERATE/STOP
 (ON/OFF) button
Indication of 
remote controller
model is on back
Distance of signal :
About 6 m
Beep(s) is (are) heard from
the indoor unit when the
signal is received.
FAN SPEED CONTROL button
PURIFIER button
INDIRECT/DIRECT button
OPERATION SELECT button
ECONO COOL button
POWERFUL button
CLOCK button
Lid
Slide the lid down
to open the remote
controller. Slide it down
further to get to the
weekly timer buttons.
WEEKLY TIMER
set buttons
TIME, TIMER set buttons
FORWARD button
BACKWARD button
RESET button
i-save button
NATURAL FLOW button
SENSOR (i-see) button
VANE CONTROL button
WIDE VANE button
INDOOR UNIT DISPLAY SECTION
Operation Indicator lamp
The operation indicator at the right side of the indoor unit indicates the operation state.
  •The following indication applies regardless of shape of the indication.
Indication
Operation state
Room temperature
    
Standby mode 
(Only during multi system 
operation)
-
  Lighted
  Blinking
     Not lighted
9-1. COOL ( ) OPERATION
(1) Press OPERATE/STOP (ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select COOL mode with OPERATION SELECT button.
(3) Press TEMPERATURE buttons TEMP   or   button to select the desired temperature. The setting range is 16 - 31°C.
1. Coil frost prevention
The compressor operational frequency is controlled by the temperature of the indoor heat exchanger to prevent the coil 
from frosting.
When the temperature of indoor heat exchanger becomes too low, the coil frost prevention mode works.
The indoor fan operates at the set speed and the compressor stops. This mode continues until the temperature of indoor 
heat exchanger rises.
2. Low outside temperature operation
When the outside temperature is lower, low outside temperature operation starts, and the outdoor fan slows or stops.
3. Indoor fan speed control
 
When the thermostat turns OFF, the indoor fan operates very Low to reduce power consumption. 
 
When the room temperature rises and the thermostat is ON, the indoor fan operates according to the settings on the 
remote controller.