Справочник Пользователя для Rigol MSO1074Z-S 4-channel oscilloscope, Digital Storage oscilloscope, MSO1074Z-S
Модели
MSO1074Z-S
RIGOL
2-96
DS1000Z Programming Guide
:TRIGger:VIDeo:MODE
Syntax
:TRIGger:VIDeo:MODE <mode>
:TRIGger:VIDeo:MODE?
:TRIGger:VIDeo:MODE?
Description
Set or query the sync type in video trigger.
Parameter
Name
Type
Range
Default
<mode> Discrete
{ODDField|EVENfield|LINE|ALINes}
ALINes
Explanation
ODDField: trigger on the rising edge of the first ramp waveform pulse in the odd
field. This type is available when the video standard is NTSC or PAL/SECAM.
EVENfield: trigger on the rising edge of the first ramp waveform pulse in the even
field. This type is available when the video standard is NTSC or PAL/SECAM.
LINE: for NTSC and PAL/SECAM video standards, trigger on the specified line in the
odd or even field; for 480P and 576P video standard, trigger on the specified line.
ALINes: trigger on all the horizontal sync pulses.
Return
Format
The query returns ODDF, EVEN, LINE or ALIN.
Example
:TRIGger:VIDeo:MODE ODDField
Related
Command
:TRIGger:VIDeo:LINE
Syntax
:TRIGger:VIDeo:LINE <line>
:TRIGger:VIDeo:LINE?
:TRIGger:VIDeo:LINE?
Description
Set or query the line number when the sync type in video trigger is LINE.
Parameter
Name
Type
Range
Default
<line>
Integer
Refer to
Explanation
1
Explanation
NTSC: 1 to 525
PAL/SECAM: 1 to 625
480P: 1 to 525
576P: 1 to 625
Return
Format
The query returns an integer.
Example
:TRIGger:VIDeo:LINE 100
Related
Command